Keysight (Agilent) Technologies N4692A Other Test Equipment

KEYSIGHT (AGILENT) TECHNOLOGIES N4692A

ECal module, 10 MHz to 40 GHz, 2.92 mm, 2-port

QUICK QUOTE
    Qty
  
  
  
SUBMIT
10MHz-40GHz,2-Port,2.92 mm Ecal Module
  • One female and one male connector, both 2.92 mm
10MHz-40GHz,2.92mm Ecal Module
  • Both 2.92 mm connectors are female on module
10MHz-40GHz,2.92 mm Ecal Module
  • Both 2.92 mm connectors are female on module
  • ANSI Z540-1-1994 Calibration
10MHz-40GHz,2-Port,2.92 mm Ecal Module
  • Both 2.92 mm connectors are female on module
  • Wooden storage box
Live Inventory Check:
N4692A PRODUCT OVERVIEW  
 

Description

The Agilent N4692A MW electronic calibration (ECal) module makes calibration of vector network analyzers fast, easy and accurate. The RF ECal system is now easily controlled by one of two methods depending on the network analyzer. The Agilent PNA and ENA series of network analyzers controls the module directly via the USB interface. The modules can also be controlled via an 85097B interface kit when used with an Agilent 8753E/ES/ET or 8720D/ES/ET. (This requires a special parallel cable and firmware Rev. 7.74).

ECal is an ideal solution for calibrating network analyzers. Performing a full two-port calibration takes less than half the time and number of connections using ECal versus mechanical cal kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.



Key Specification

  • 10 MHz to 40 GHz frequency range
  • USB interface for direct control with PNA and ENA series of network analyzers
  • Alternative 85097B interface when used with other analyzers
  • Fast calibration
  • Full two-port calibration with a single connection
  • Reduced connector wear
  • NIST traceable accurate calibrations
  • Reliable solid-state switching

N4692A OPTIONS (13)
133118False133120False133122False298459False133125False133130False298460False154429False154432False76176False79690False80436False158551False
N4692A-00A Add 2.92 mm adapters
N4692A-00F Both 2.92 mm connectors are female on module
N4692A-00M Both 2.92 mm connectors are male on module
N4692A-0B0 Download the product manual from the Keysight website
N4692A-150 Wooden storage box
N4692A-A6J ANSI Z540-1-1994 Calibration
N4692A-ABA Printed manual English
N4692A-M0F One female and one male connector, both 2.92 mm
N4692A-UK6 Commercial calibration certificate with test data
R-50C-011-3 Calibration Assurance Plan - Return to Keysight - 3 years
R-50C-011-5 Calibration Assurance Plan - Return to Keysight - 5 years
R-50C-016-3 Keysight Calibration + Uncertainties + Guardbanding - 3 years
R-50C-016-5 Keysight Calibration + Uncertainties + Guardbanding - 5 years
N4692A RESOURCES LIBRARY  
 
N4692A DOCUMENTS
N4692A PRODUCT Q & A  
 
HAVE QUESTIONS ABOUT THIS PRODUCT?
Ask a Microlease Expert

Item has been added to your Quote Cart.

    
Item has been added to your Shopping Cart.

    
Item has been added to your Shopping Cart.