Keysight (Agilent) Technologies N4694A RF Network Analyzers

KEYSIGHT (AGILENT) TECHNOLOGIES N4694A

1.85 mm ECal module 67 GHz, 2-port

QUICK QUOTE
    Qty
  
  
  
SUBMIT
1.85mm Ecal Module 10MHz to 67GHz
  • 10 MHz to 67 GHz ECal, one male connector and one female connector
10MHz-67GHz,2-Port,1.85mm Ecal Module
  • Add 1.85 mm adapters
  • Wooden storage box
  • 10 MHz to 67 GHz ECal, one male connector and one female connector
N4694A
1.85mm Ecal Module 10MHz to 67GHz (2 port)
10MHz-67GHz 2-Port Ecal Module 1.85mm
  • 10 MHz to 67 GHz ECal, both connectors female
  • Wooden storage box
Live Inventory Check:
N4694A PRODUCT OVERVIEW  
 

Description

The Agilent N4694A MW electronic calibration (ECal) module makes calibration of vector network analyzers fast, easy and accurate. The RF ECal system is now easily controlled by one of two methods depending on the network analyzer. The Agilent PNA and ENA series of network analyzers controls the module directly via the USB interface. The modules can also be controlled via an 85097B interface kit when used with an Agilent 8753E/ES/ET or 8720D/ES/ET. (This requires a special parallel cable and firmware Rev. 7.74).

ECal is an ideal solution for calibrating network analyzers. Performing a full two-port calibration takes less than half the time and number of connections using ECal versus mechanical cal kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.



Key Specification

  • 10 MHz to 67 GHz frequency range
  • USB interface for direct control with PNA and ENA series of network analyzers
  • Alternative 85097B interface when used with other analyzers
  • Fast calibration
  • Full two-port calibration with a single connection
  • Reduced connector wear
  • NIST traceable accurate calibrations
  • Reliable solid-state switching

N4694A OPTIONS (17)
154446False154447False154448False298465False154450False154452False154453False298466False261603False261604False261605False154454False154457False76178False79692False80438False158553False
N4694A-00A Add 1.85 mm adapters
N4694A-00F 10 MHz to 67 GHz ECal, both connectors female
N4694A-00M 10 MHz to 67 GHz ECal, both connectors male
N4694A-0B0 Download the product manual from the Keysight website
N4694A-150 Wooden storage box
N4694A-1A7 Calibration + Uncertainties + Guardbanding (Not Accredited)
N4694A-A6J ANSI Z540-1-1994 Calibration
N4694A-ABA Printed manual English
N4694A-HFF DC to 67 GHz ECal, both connectors female
N4694A-HMF DC to 67 GHz ECal, one male connector and one female connector
N4694A-HMM DC to 67 GHz ECal, both connectors male
N4694A-M0F 10 MHz to 67 GHz ECal, one male connector and one female connector
N4694A-UK6 Commercial calibration certificate with test data
R-50C-011-3 Calibration Assurance Plan - Return to Keysight - 3 years
R-50C-011-5 Calibration Assurance Plan - Return to Keysight - 5 years
R-50C-016-3 Keysight Calibration + Uncertainties + Guardbanding - 3 years
R-50C-016-5 Keysight Calibration + Uncertainties + Guardbanding - 5 years
N4694A RESOURCES LIBRARY  
 
N4694A PRODUCT Q & A  
 
HAVE QUESTIONS ABOUT THIS PRODUCT?
Ask a Microlease Expert

Item has been added to your Quote Cart.

    
Item has been added to your Shopping Cart.

    
Item has been added to your Shopping Cart.