Keysight (Agilent) Technologies N5244A Other Test Equipment

KEYSIGHT (AGILENT) TECHNOLOGIES N5244A

10 MHz to 43.5 GHz PNA-X network analyzer

Frequency range : 10 MHz to 43.5 GHz
# of ports : 1
Noise Floor/Dynamic range : -111 dBm to +30 dBm
output power : -5 dBm to +13 dBm
Number of ports : 2 to 4
Dynamic Range : to 129 dB
QUICK QUOTE
    Qty
  
  
  
SUBMIT
10 MHz to 43.5 GHz PNA-X network analyzer
  • Time-domain measurements
  • Frequency offset measurements
  • Vector and scalar calibrated converter measurements
  • Embedded LO measurements
Show More
10MHz-43.5GHz,4-Port,PNA-X Network Analyser
  • Add IF inputs
  • Frequency offset measurements
  • 4 ports, dual source
  • Add extended power range and bias-tees to 4 port analyzer
Show More
10MHz to 43.5GHz PNA-X Network Analyser
  • 2 ports, single source
N5244A
10MHz to 43.5GHz PNA-X Network Analyser
10 MHz to 43.5 GHz PNA-X network analyzer
  • Frequency offset measurements
  • Vector and scalar calibrated converter measurements
  • Embedded LO measurements
  • 4 ports, dual source
Show More
Live Inventory Check:
N5244A PRODUCT OVERVIEW  
 

Description

World´s widest range of single-connection measurement applicationsThe PNA-X network analyzer is the world´s most integrated and flexible single-connection microwave test engine for measuring active devices such as amplifiers, mixers, and frequency converters. You can choose from five frequency models to meet your specific device test needs: 13.5, 26.5, 43.5, 50, and 67 GHz. The PNA-X provides unrivaled configurability with a built-in second source, combiner, and internal signal-routing switches.

Applications:
  • S-parameters (CW and pulsed)
  • Noise figure
  • Gain compression
  • Intermodulation and harmonic distortion
  • Conversion gain/loss
  • True-differential stimulus
  • Millimeter-wave
  • Nonlinear waveform and X-parameter® characterization
  • Antenna test
Key Features & Specifications
  • 10 MHz to 43.5 GHz
  • 2- or 4-ports with two built-in sources
  • 126 dB system and 129 receiver dynamic range, 32,001 points, 200 channels, 15 MHz IF bandwidth
  • High output power (+18 dBm), low harmonics (-60 dBc) and a wide power sweep range (38 dB)
  • Best dynamic accuracy: 0.1 dB compression with +15 dBm input power at the receiver
  • Low noise floor of -111 dBm at 10 Hz IF bandwidth

N5244A OPTIONS (68)
278770False136042False136044False278771False136046False136048False136050False136052False136054False136056False136087False136089False136091False136093False136095False136097False136099False278772False278773False298519False298521False136101False136103False136105False136107False136109False136111False136113False136115False136117False136119False136121False136123False136125False136127False136129False136131False136133False136135False136138False136153False136155False136157False136206False136208False136209False139325False139377False139430False139483False32733False34222False34707False35185False35538False274382False76210False79724False274548False278835False278853False80453False81573False274737False231047False274872False23221False23326False
N5244A-007 Automatic Fixture Removal
N5244A-008 Pulsed-RF Measurements
N5244A-010 Time-domain measurements
N5244A-015 Dynamic Uncertainty for S-Parameter Measurements
N5244A-020 Add IF inputs
N5244A-021 Add pulse modulator to internal first source
N5244A-022 Add pulse modulator to internal second source
N5244A-025 Add four internal pulse generators
N5244A-028 Noise figure measurements using standard receivers
N5244A-029 Fully-Corrected Noise-Figure Measurements to 50 GHz
N5244A-080 Frequency offset measurements
N5244A-082 Scalar calibrated converter measurements
N5244A-083 Vector and scalar calibrated converter measurements
N5244A-084 Embedded LO measurements
N5244A-086 Gain compression measurements
N5244A-087 Intermodulation distortion measurements
N5244A-088 Source phase control
N5244A-089 Differential and I/Q devices application
N5244A-090 Spectrum Analyzer
N5244A-093 Extended Spectrum Analyzer to 110 GHz
N5244A-094 Extended Spectrum Analyzer above 110 GHz
N5244A-118 Fast CW mode
N5244A-1A7 Calibration + Uncertainties + Guardbanding (Not Accredited)
N5244A-1CM Rack mount kit for installation without handles
N5244A-1CP Rack mount kit for installation with handles
N5244A-200 2 ports, single source
N5244A-219 Add extended power range and bias-tees to 2 port analyzer
N5244A-224 Add internal second source, combiner and mechanical switches to 2-port analyzer
N5244A-301 Application for use with standard CalPods
N5244A-302 Application for use with temperature-characterized CalPods
N5244A-400 4 ports, dual source
N5244A-419 Add extended power range and bias-tees to 4 port analyzer
N5244A-423 Add internal combiner and mechanical switches to 4-port analyzer
N5244A-460 Integrated true-mode stimulus application
N5244A-510 Nonlinear component characterization, full frequency range
N5244A-514 Nonlinear x-parameters
N5244A-518 Nonlinear pulse envelope domain
N5244A-520 Arbitrary load impedance X-parameters
N5244A-551 N-port calibrated measurements
N5244A-629 Noise figure accessories
N5244A-897 Built-in performance test software for inclusive calibration, perpetual license
N5244A-898 Built-in performance test software for standards compliant calibration, perpetual license
N5244A-A6J ANSI Z540-1-1994 Calibration
N5244A-H08 Pulsed - RF measurements
N5244A-RMKT Refurbished product
N5244A-UK6 Commercial calibration certificate with test data
N6171A MATLAB Software
N6171A-M01 MATLAB-Basic Package, individual license - node-locked
N6171A-M02 MATLAB-Standard Package, individual license - node-locked
N6171A-M03 MATLAB-Advanced Package, individual license - node-locked
PS-S10 Remote scheduled productivity assistance. Select 1 to 999 hours.
PS-S20 Startup assistance
PS-S20-01 Recommended Startup assistance
PS-T10-PNA PNA operator training for 8 students at the customer's site , H7215B-203
PS-T12-PNA PNA programming for 8 students at the customer's site , H7215B-204
R-50C-011-10 Calibration Assurance Plan - Return to Keysight - 10 years
R-50C-011-3 Calibration Assurance Plan - Return to Keysight - 3 years
R-50C-011-5 Calibration Assurance Plan - Return to Keysight - 5 years
R-50C-011-7 Calibration Assurance Plan - Return to Keysight - 7 years
R-50C-011-MU-3 Keysight Calibration + Uncertainties - 3 years
R-50C-011-MU-5 Keysight Calibration + Uncertainties - 5 years
R-50C-016-3 Keysight Calibration + Uncertainties + Guardbanding - 3 years
R-50C-016-5 Keysight Calibration + Uncertainties + Guardbanding - 5 years
R-51B-001-10Z Warranty Assurance Plan - Return to Keysight - 10 years
R-51B-001-5Z Warranty Assurance Plan - Return to Keysight - 5 years
R-51B-001-7Z Warranty Assurance Plan - Return to Keysight - 7 years
R-51C-001-1CU Onsite Warranty - 1 year
R-51C-001-3CU Onsite Warranty - 3 years
N5244A ACCESSORIES (2)
N1966A
Pulse/IO Adaptor Qty  
N6171A
MATLAB for Signal Analysis Qty  
N5244A RESOURCES LIBRARY  
 
  • N5244A
    N5244A DOCUMENTS
  • N5244A PRODUCT Q & A  
     
    HAVE QUESTIONS ABOUT THIS PRODUCT?
    Ask a Microlease Expert

    Item has been added to your Quote Cart.

        
    Item has been added to your Shopping Cart.

        
    Item has been added to your Shopping Cart.